Programm & Abstracts                 "Innovationen in der Augenheilkunde"

Aktuelle Tagungsinformationen
   News and Updates

Anmeldung zur Tagung
   Registration
Hotelbuchung
   Hotel Registration
Grußwort
   Welcome address
Beteiligte Gesellschaften
   Societies involved
Eröffnung des Kongresses
   Opening Ceremony
Preise
   Awards
Wissenschaftliches Programm
   Scientific program
Posterpräsentationen
   Poster Presentation
Kurse
   Courses
Begleitende Veranstaltungen
   Collateral Events
Rahmenprogramm
   Social program
Jubiläumsparty
   Jubilee Party
DOG Information
   DOG Information
Allgemeine Informationen
   General Information
Autorenindex
   Index of Authors
Ausstellerliste
   Exhibitors
Sponsoren
   Sponsors
Teilnahmegebühren
   Registration fees
Impressum



DOG Homepage

Cataract Surgery in Relative Anterior Microphthalmus (RAM): A Review on Anatomy, Associated Pathology and Complications

Völcker H. E., Auffarth G. U.,
Ruprecht-Karls-Universität Heidelberg, Universitäts-Augenklinik (Heidelberg)

Background: Naumann has coined the term relative anterior microphthalmus (RAM) for eyes with a dysproportional small anterior segment but no further malformation. Those eyes are charcterized by corneal diameters of <11mm and total axial length of >20mm.
Patients and Methods: To evaluate and define morphometrical data and risk factors for cataract surgery in patients with relative anterior microphthalmus (RAM) 112 cataract operations of 79 patients with RAM were analysed. Associated ocular pathology (such as glaucoma, previous surgical interventions, etc.) and complications of cataract surgery were recorded.
Results: Average corneal diameter was 10.7±0.34mm, AC-depth was 2.20±0.49 and average lens thickness 5.05± 0.45mm. Fifty five percent of the patient revealed myopic refraction. There was a high incidence of glaucoma (77%), cornea guttata (46.6%) and Pseudoexfoliation syndrome (16%) in the RAM-group. Sixty percent of patients previously underwent glaucoma surgery. After cataract surgery 51.2% opf patients achieved a visual acuity of >0.5; 69.8% >0.4. The IOP was preoperatively 16.5±5.8 mmHg (with 1.3±1.4 antiglaucomatous drugs). Postoperatively IOP dropped significantly to 13.6±3.2 mmHg (with significant reduction of treatment (0,6±1,0) (p<0.01). The anterior chamber depth deepened from 2.42±0.47mm to 3.33±0.72mm.
Conclusions: The special anatomical situation in RAM is responsible for the high incidence of glaucoma and postoperative complications after cataract surgery. Cataract surgery helps not only to restore vision but also facilitates handling and regulation of intraocular pressure.

Zurück/Back